The solar self-sufficiency calculator answers the independence question, not the profitability question: how much of your electricity use can PV and battery storage cover on site?

Quick mode preserves the existing input and calculation. Location mode captures site, system capacity, roof and explicitly disclosed losses.
Annual generation stays unchanged. This allocates it across typified months and hours for the self-use calculation; it is not a weather year.
You can find this number on your electricity bill. It limits the maximum possible self-sufficiency rate.
Without yield data, you can use PV size in kWp × roughly 900–1,000 kWh/kWp/year as an assumption. Location and orientation can change actual yield.
This allocates annual consumption across typified hours. It does not replace measured interval data.
0 means: PV without battery only. The calculation shows from the hourly profile how much PV surplus becomes additionally usable.
Includes charging and discharging losses. A lower efficiency reduces additional on-site supply and the self-sufficiency rate.
Result-relevant detailsTechnical data, roof planes and yield lossesReview power limits, technical loads, battery reserve and yield losses
The base calculation remains comparable with previous results. Custom values add power limits, own consumption and a battery reserve.
Guidance: 20 years, 1% calendar ageing per year, a 70% cycle component after 6,000 full cycles and a warranty comparison against 70% after 10 years; no automatic replacement. These are editable scenario values, not a manufacturer promise.
Solar Self-Sufficiency Calculator: preparing the calculation logicThe calculation starts only after you submit the form. Until then, Calc‑World deliberately shows no provisional result. The method, interpretation and model limits remain readable on this page.
Model scope, review and sourcesScope, model baseline and responsible sources
Transparency

Scope and assumptions

The model uses a documented international reference basis. Check whether that reference fits the person, location and decision being assessed.

Model
Reference model
Reference region
International
Currency
No monetary calculation
Units
No unit conversion needed
Reference basis
European Commission Joint Research Centre (PVGIS 5.3)
Responsibility & review

Who is responsible for this model

Find out who is responsible for this content, what has been checked, how the calculation works and which primary sources it uses. If no external professional review is named, none has taken place.

Responsible editor
Jens Marx
Latest editorial and technical review
Review
Internal editorial and technical review
Calculation basis
Battery lifecycle model v1

Review scope: Language, sources, inputs, worked example, model limits and technical output were reviewed. No external case-specific professional review was performed.

FAQ

FAQ about Solar Self-Sufficiency Calculator

How do self-consumption and self-sufficiency differ?

The self-consumption rate divides solar energy used on site by total PV generation. The self-sufficiency rate divides the same covered energy by electricity demand. The two percentages can therefore differ even though they use the same energy flows.

Why are total self-sufficiency and household coverage separate?

In technical mode, total self-sufficiency includes household demand, system demand and battery standby demand. Household coverage uses household demand alone as its denominator, making the effect of technical loads visible instead of hiding it in one percentage.

How are equivalent full cycles and battery ageing calculated?

Equivalent full cycles are total energy discharged from the battery divided by its originally usable capacity, so partial discharges add up. Calendar ageing develops with time, while cycle-related ageing follows battery use. The model combines both effects when projecting remaining capacity.

What do the warranty comparison and battery reserve mean?

The warranty comparison places modeled retention of the original battery at the earlier entered time or cycle boundary beside the contractual threshold; it does not decide a warranty claim. The reserve keeps part of the capacity already entered as usable unavailable for discharge, reduces modeled self-sufficiency and does not promise backup operation.

Is a high self-sufficiency rate always economical?

No. More independence can be valuable, but profitability depends on battery cost, electricity price and grid-export value.

How do I compare several results?

Calculate your first result, then open “Compare your scenarios and document the evidence” below it and select “Capture displayed result”. Change the inputs, calculate again and capture the next result. You can compare up to three results. Leaving or reloading the page clears the captured scenarios and notes unless you export them first.

How do I save and reopen a comparison?

In the scenario comparison, “Export comparison (CSV)” downloads a table for documentation. To reopen the comparison here later, use “Save archive for later” to download a JSON file, then import it in the same calculator. Imported results are unverified archive values. Select “Restore inputs and recalculate” and check the current result before capturing it again.

How do I change input units?

Choose the unit beside the input: W or kW for power. Values already entered are converted to the equivalent amount.

How do I check my own energy readings?

Open “Check measured consumption, PV and tariff costs” below the result. Download the CSV template, select your measurement interval and import a complete, consecutive series. Each row needs an interval-start timestamp with its UTC offset and energy in kWh, not a meter total or power reading. PV generation and complete variable prices are optional. Enter fixed fees for that exact period. This separate check does not extrapolate a year or replace the battery, vehicle or heat-pump calculation. Coarse intervals can overstate simultaneous PV use.