Decision guide

Solar, heat pump and EV planning – with optional air conditioning

A large solar surplus in summer does not automatically supply an electric car at night or a heat pump in winter. All the devices share the same roof’s output. Whether an extra battery or different charging controls help depends on when electricity is needed and what the change costs.

Family home with rooftop solar panels and a small garden.
Illustrative image

Quick answer

Compare additional costs for the same energy needs

Compare one change with the same heating, driving and cooling needs. Do savings cover the extra cost? Net present value converts future savings and expenses to today’s value at your comparison rate, then subtracts the upfront investment. More self-sufficiency alone does not prove a financial benefit.

What matters

Define the starting system honestly

Treat the heat pump and EV as already present or separately planned in both scenarios. Enter zero heat or zero mileage if you do not use the corresponding device. The model does not compare their purchase against a boiler or combustion car; those decisions also require purchase prices, fuel, maintenance and possibly financing.

Which device gets the solar power first?

Within each model hour, system consumption and household demand have priority, followed by the heat pump, home charging and optional cooling. The battery can serve the same loads within its limits. These are declared dispatch rules, not an optimisation guarantee. Add the load-specific direct, battery and grid quantities to reconcile the whole-home balance.

Check presence before promising solar charging

Controlled charging stays inside the same arrival and departure window as immediate charging. It can favor hours with modeled solar surplus, but cannot make a commuter car available at midday. Session energy is bounded by the vehicle capacity, arrival and target charge, charging efficiency and AC power. Any unmet home target is priced externally to preserve the same driving distance.

Treat cooling as a separate seasonal load

Switch on air conditioning only when it belongs to the project. Enter seasonal electricity and its months and daily window; the planner uses every day within that season. Remove the same electricity from general household demand. A reversible heat pump can provide the calculated cooling demand, but room temperatures and simultaneous heating/cooling limits need a separate equipment assessment.

Understand the time and weather assumptions

The shared model uses a synthetic non-leap year with hourly steps, beginning on a Monday and without daylight-saving changes. PV and heating patterns reflect northern-hemisphere seasons. Annual yield may come from your measurements or a local assessment, but the planner does not turn it into measured hourly data. In location mode, PVGIS supplies the starting system’s annual yield and twelve monthly values. Both variants use the same roof planes and monthly shares. Additional PV kWh scale this profile; extensions with a different orientation need separate planning. Hourly generation and consumption profiles remain model assumptions.

Compare only the extra costs

Enter only payments caused by the selected change. An existing system’s purchase price cancels out. Additional maintenance, a replacement in a named year and a justified residual value are included. Positive annual savings may decline by the stated sensitivity percentage; that assumption does not regenerate physically aged hourly profiles. Tariffs remain constant and financing, tax effects and subsidies are excluded.

Examples and comparisons

A battery reduces grid imports but does not recover its cost

Which change would you like to test?Add or enlarge a battery
Additional investment for the change€4,000
Comparison period20 years
Additional annual benefit after maintenance€237.46
Net present value of the change€-2,041.02

Load this example’s inputs in the calculator. Review them, calculate the result, then adapt the values to your own case.

Illustrative comparison

When is the car home for solar charging?

Shared energy assumptions: 9,000 kWh solar output with a south-facing profile, 3,500 kWh household demand with a typical daily pattern and 14,000 kWh heat at SPF 3.5 with a mixed heat-pump profile. The car travels 15,000 km at 18 kWh/100 km, with 80% of charging planned at home. Charging starts on arrival at up to 11 kW and 90% efficiency; the vehicle battery holds 60 kWh, with 40% charge on arrival and an 80% target. Only the charging window changes, on five days per week. Results show grid imports with a 5 kWh battery added to a home without storage: 3 kW charge/discharge power, 90% round-trip efficiency, 10% reserve and 5 W standby demand. Inverter capacity is 10 kW; cooling is off. Unmet home charging is supplied externally and reported separately.

At home: 18–7

Annual grid imports with added battery
6,061 kWh

External charging per year: 600 kWh

Load these inputs

At home: 10–17

Annual grid imports with added battery
5,022 kWh

External charging per year: 600 kWh

Load these inputs

At home: 10–11

Annual grid imports with added battery
5,022 kWh

External charging per year: 600 kWh

Load these inputs

These are model cases, not reports from real households or market forecasts. The link loads all inputs so you can check, calculate and adapt the case.

Cost sensitivity

A higher quote changes the investment case

Sensitivity check · only one input changedAdditional investment for the change → Net present value of the change

Direct comparison

Data points for the two calculated scenarios: Additional investment for the change and Net present value of the change
ScenarioAdditional investment for the changeNet present value of the change
Scenario 1€4,000-€2,041.02
Scenario 2€5,000-€3,041.02
Change from scenario 1 to scenario 2-€1,000 · -49% relative

Also verify before making a decisionOnly initial investment changes. Energy use, charging times, maintenance and replacement assumptions remain the same; these are scenarios rather than market forecasts.

Assess your case

Does the improvement save enough to cover its cost?

If solar share rises but net present value is negative

Check a smaller intervention or a lower quotation. The largest battery is not automatically the best option.

If external charging increases

Confirm access and the actual charging tariff. A lower home electricity bill can simply move costs elsewhere.

If winter imports remain high

Review insulation, heating efficiency and winter solar generation. Daily battery storage cannot bridge a seasonal energy deficit.

Checklist

Collect the project evidence

  • Household demand excludes heat-pump, driving and cooling electricity.
  • Yield, charging availability and tariffs are documented for the actual site.
  • The quotation covers only the selected change, including installation and future replacement.
  • A lower-benefit case and practical access to external charging have been checked.

Common mistakes

Avoid misleading savings

Count one solar kilowatt-hour several times

Do not add standalone heat-pump, EV and cooling savings. They compete for the same solar supply and storage.

Use the annual saving as a purchase limit

A yearly benefit is not the amount available to pay for hardware. Review its value today over the selected period, including maintenance and replacement.

Hide charging shortfalls

A short home window cannot reduce the energy needed for the same journey. External charging is included and must also be feasible in practice.

Keep battery costs for a charging controller

When changing the intervention, replace investment, maintenance and replacement assumptions with the corresponding quotation. Default values are illustrative.

What if the additional equipment costs more?

What changes when additional investment costs are 20 percent higher but energy demand stays the same? Compare net present value and confirm that grid imports and solar share remain unchanged. Then calculate a shorter period for charging at home separately. Energy the car cannot charge at home must still be counted as charging elsewhere.

  • I can support the roof and panel areas, shading, losses and consumption figures with documents or measurements.
  • Quoted costs include installation, connection and any battery replacement.
  • I have checked winter grid use, actual operating times and power limits. Covering much of the year with my own solar power does not provide protection during an outage.

Calculator for this guide

Check the change against your quotation

Review winter imports, externally charged electricity and the incremental net present value. Recalculate with higher costs and a lower energy benefit before choosing a system.
Open the matching calculator

How the calculation works

Calculation

Calculation method and model limits

The model first allocates energy jointly, then compares the whole-system bill and future incremental cash flows. You pay for the improvement upfront, while avoided electricity purchases save money later. Net present value uses your comparison rate to assess these costs and savings at the investment date. With a positive rate, a saving in year ten contributes less than an equal saving in year one. A zero rate leaves every amount unchanged. This treatment reflects when electricity savings arrive; it does not remove inflation from them.

1
Define demand

Convert useful heat with the stated seasonal efficiency and driving energy with charging losses.

2
Allocate each solar unit once

Apply the same hourly household, heating and optional cooling loads, then charging windows, storage limits and imports.

3
Account for all electricity costs

Price grid electricity and any external charging, and subtract the corresponding export revenue.

4
Evaluate the future change

Value each year's extra savings and costs at the investment date using the comparison rate. Include upfront cost, maintenance, replacement and residual value.

The comparison shows energy supply, first-year savings and the benefit of the additional investment valued today.

Simplified formula

Heat-pump electricity = useful heat / seasonal performance factor. Charging electricity = kilometers / 100 × driving consumption / charging efficiency. Net energy cost = grid purchases + external charging − export revenue. Incremental net present value = discounted savings less maintenance, initial and replacement expenditure, plus residual value.

Units and conversions

1 kW equals 1,000 W. Power describes the rate of energy use or generation; energy in kWh equals average power in kW × time in hours. 100 cents equal one euro or dollar, 100 pence equal one pound and 100 rappen equal one Swiss franc. A price per kWh is multiplied by the energy consumed. All monetary amounts in a calculation must use the same currency. No exchange-rate conversion is applied.

Transparency

Scope and assumptions

The model uses a documented international reference basis. Check whether that reference fits the person, location and decision being assessed.

Calculation
Reference model
Applies to
International
Currency
Selectable display currency; no exchange-rate conversion
Units
Selectable unit display; metric, US and UK units are supported
Based on
Calc-World typified hourly profiles; HTW Berlin and JRC methodological references
Calculation baseline

The examples use fixed reference values. For your own comparison, all prices must use the same currency. Changing currency does not convert the amounts.

Questions about the shared energy planner

Why cannot I add savings from the separate calculators?

The heat pump, car and household compete for the same solar generation. This planner allocates every kilowatt-hour once and balances direct use, storage losses, exports and grid imports together.

What does a negative net present value mean?

The improvement's electricity savings are insufficient to recover its additional investment, maintenance and replacement costs after allowing for residual value and the timing of each amount at your chosen comparison rate. This is a comparison scenario, not a guaranteed forecast. Check quotations and calculate an adverse case.

Does this compare a boiler and petrol car against a heat pump and EV?

No. Both variants use the same heat pump and electric car, already present or separately planned. Their purchase, financing and alternative fuel costs belong in the linked heating-system and vehicle comparisons.

Are these measured profiles or a real weather year?

No. Annual quantities are allocated to 8,760 typified hours. Seasonal patterns reflect northern-hemisphere assumptions. Location, shading, temperature and driving schedules can differ. Location mode fetches PVGIS monthly values and derives typified hours. Quick mode continues to use your own annual yield. Failed requests do not create a replacement value.

What happens if the charging window is too short?

Home-charging demand that cannot be met is charged at the external tariff. This preserves equal driving distance but assumes external charging is actually available. The result explicitly identifies that quantity.

Can I include cooling by a reversible heat pump?

Yes, enter its separate cooling electricity in the optional air-conditioning section. The heat input covers heating and hot water only. Do not enter the same cooling electricity in household or heating demand as well. Heating/cooling switching limits require an equipment-specific check.

Continue planning

Check the equipment decision separately

Use a dedicated comparison for heating-system purchase, the car or room cooling capacity.

Editorial method

We test the worked example automatically with the same logic used by the calculator. Sources, inputs, rounding and model limits are listed separately. This does not replace case-specific professional advice.

Editorial responsibility, update & sources

Responsible editor: Jens Marx

Source scope: The planner can use entered annual solar yield or PVGIS location-based monthly yield projections. These are distributed across typified hours together with the selected consumption schedules; they are not a measured household load series or an hourly weather forecast. German HTW and European JRC sources explain this modelling context. Tariffs, equipment, costs and local installation requirements need project-specific review.

Model assumptions, worked examples, language and technical output were reviewed internally. No independent system design or external professional assessment of your particular project has been carried out.