Calculator

Solar, Heat Pump & EV Planner – Optional Air Conditioning

Compare PV, storage and home charging for your whole home, with optional air conditioning.

Start calculating – enter your values
Family home with rooftop solar panels and a small garden.
Illustrative image
Inputs

Calculate now

Guide & worked examples

How would extra solar panels, a battery or solar-aware charging affect your whole home? Compare one specific change with your starting system. Household demand, useful heat and driving distance stay equal. The calculation allocates the same solar generation across all loads and accounts for foregone export payments.

Display currencyChoose the currency for inputs and results. Numeric values and the model basis stay unchanged; no exchange-rate conversion is applied.
UnitsMetric units are the international default. Switch to US or UK units for distance, consumption and energy or fuel price when your comparison uses them.
Quick mode preserves the existing input and calculation. Location mode captures site, system capacity, roof and explicitly disclosed losses.
Use measured yield or a documented yield calculation. 0 means no existing PV. Monthly and hourly allocation remains typified.
Useful heat, not fuel input. Account for boiler losses before using gas consumption. 0 means no heat pump.
Enter EV efficiency in the displayed unit (kWh/100 km); include charging losses in the realistic value.
Replace with the quote for the selected change, including installation. Exclude already-paid system costs.
Result-relevant detailsCharging times, equipment and future costsReview the defaults for your home and selected quotation
Converts future savings and costs to their value today: at 3%, 103 in one year is equivalent to 100 today. At 0%, amounts stay unchanged. This is not an inflation adjustment.
Solar, Heat Pump & EV Planner – Optional Air Conditioning: preparing the calculation logicThe calculation starts only after you submit the form. Until then, Calc‑World deliberately shows no provisional result. The method, interpretation and model limits remain readable on this page.
Model scope, review and sourcesScope, model baseline and responsible sources
Transparency

Scope and assumptions

The model uses a documented international reference basis. Check whether that reference fits the person, location and decision being assessed.

Model
Reference model
Reference region
International
Currency
Display currency EUR; no exchange-rate conversion
Units
Metric display; metric, US and UK units are supported
Reference basis
Calc-World typified hourly profiles; HTW Berlin and JRC methodological references
Reviewed model baseline
Responsibility & review

Who is responsible for this model

Find out who is responsible for this content, what has been checked, how the calculation works and which primary sources it uses. If no external professional review is named, none has taken place.

Responsible editor
Jens Marx
Latest editorial and technical review
Review
Internal editorial and technical review
Calculation basis
home-energy-planner-1 · energy-profile-core-2 · Energy-device operation model v1 · cooling-time-profile-1 · cw-home-energy-planner-2026-v1

Review scope: Model assumptions, worked examples, language and technical output were reviewed internally. No independent system design or external professional assessment of your particular project has been carried out.

Model maintenance: Model version cw-home-energy-planner-2026-v1 · Baseline 16 September 2026: shared hourly dispatch, equal heat and mileage, incremental cost comparison. Typified northern-hemisphere profiles, not a weather year. Model review by 16 September 2027.

FAQ

FAQ about Solar, Heat Pump & EV Planner – Optional Air Conditioning

Why cannot I add savings from the separate calculators?

The heat pump, car and household compete for the same solar generation. This planner allocates every kilowatt-hour once and balances direct use, storage losses, exports and grid imports together.

What does a negative net present value mean?

Under the stated assumptions, additional savings do not cover additional expenditure when all later amounts are converted to their value today using the comparison rate. This is a comparison scenario, not a guaranteed forecast. Check quotations and calculate an adverse case.

Does this compare a boiler and petrol car against a heat pump and EV?

No. Both variants use the same heat pump and electric car, already present or separately planned. Their purchase, financing and alternative fuel costs belong in the linked heating-system and vehicle comparisons.

Are these measured profiles or a real weather year?

No. Annual quantities are allocated to 8,760 typified hours. Seasonal patterns reflect northern-hemisphere assumptions. Location, shading, temperature and driving schedules can differ. In location mode, PVGIS supplies the starting system’s annual yield and twelve monthly values. Both variants use the same distribution; additional PV kWh scale that profile. Hourly values remain model assumptions, not measurements.

What happens if the charging window is too short?

Home-charging demand that cannot be met is charged at the external tariff. This preserves equal driving distance but assumes external charging is actually available. The result explicitly identifies that quantity.

Can I include cooling by a reversible heat pump?

Yes, enter its separate cooling electricity in the optional air-conditioning section. The heat input covers heating and hot water only. Do not enter the same cooling electricity in household or heating demand as well. Heating/cooling switching limits require an equipment-specific check.

How do I compare several results?

Calculate your first result, then open “Compare your scenarios and document the evidence” below it and select “Capture displayed result”. Change the inputs, calculate again and capture the next result. You can compare up to three results. Leaving or reloading the page clears the captured scenarios and notes unless you export them first.

How do I save and reopen a comparison?

In the scenario comparison, “Export comparison (CSV)” downloads a table for documentation. To reopen the comparison here later, use “Save archive for later” to download a JSON file, then import it in the same calculator. Imported results are unverified archive values. Select “Restore inputs and recalculate” and check the current result before capturing it again.

How do I change input units?

Choose the unit beside the input: W or kW for power, currency units or cents per kWh (pence for GBP; rappen for CHF). Values already entered are converted to the equivalent amount. Select your offer's currency first; no exchange-rate conversion is applied.