Calculator

Solar Air Conditioning Calculator

Plan cooling by time of day: direct PV, battery supply, grid use and additional electricity cost.

Start calculating – enter your values
Family home with rooftop solar panels and a small garden.
Illustrative image
Inputs

Calculate now

Guide & worked examples

How much air-conditioning electricity can your PV system supply at the right time? Compare cooling without PV, with PV alone and with your battery. Household demand, cooling energy and tariffs stay consistent across the comparison, including the optional operating-window shift.

Display currencyChoose the currency for inputs and results. Numeric values and the model basis stay unchanged; no exchange-rate conversion is applied.
UnitsMetric units are the international default. Switch to US or UK units for floor area, ceiling height, temperatures and rated cooling capacity when your comparison uses them.
Enter a measured value or a scenario. It is allocated across the chosen months, days and hours; the schedule does not create additional annual demand.
1 = January, 12 = December. The season can cross the year boundary.
Whole hours in the model day. A window crossing midnight uses the early and late hours of each selected day. No daylight-saving adjustment.
The model serves this demand before cooling. Subtract cooling electricity if it is already included. EVs and heat pumps are not separately controlled loads here.
Enter 0 for PV without a battery. The comparison shows operation with and without this battery; it does not assess a purchase or battery payback.
Foregone export revenue is deducted from avoided grid cost. A high export tariff can make the additional solar value negative.
Quick mode preserves the existing input and calculation. Location mode captures site, system capacity, roof and explicitly disclosed losses.
Annual generation stays unchanged. This allocates it across typified months and hours for the self-use calculation; it is not a weather year.
Result-relevant detailsTime comparison and technical limitsStandard assumptions active
Negative means earlier; positive means later. Electricity use and selected calendar days stay unchanged. Check whether comfort, the building and the equipment allow this change.
This allocates annual consumption across typified hours. It does not replace measured interval data.
The base calculation remains comparable with previous results. Custom values add power limits, own consumption and a battery reserve.
Solar Air Conditioning Calculator: preparing the calculation logicThe calculation starts only after you submit the form. Until then, Calc‑World deliberately shows no provisional result. The method, interpretation and model limits remain readable on this page.
Model scope, review and sourcesScope, model baseline and responsible sources
Transparency

Scope and assumptions

The model uses a documented international reference basis. Check whether that reference fits the person, location and decision being assessed.

Model
Reference model
Reference region
International
Currency
Display currency EUR; no exchange-rate conversion
Units
Metric display; metric, US and UK units are supported
Reference basis
European Commission Joint Research Centre (PVGIS 5.3)
Reviewed model baseline
Responsibility & review

Who is responsible for this model

Find out who is responsible for this content, what has been checked, how the calculation works and which primary sources it uses. If no external professional review is named, none has taken place.

Responsible editor
Jens Marx
Latest editorial and technical review
Review
Internal editorial and technical review
Calculation basis
pv-cooling-1 · cooling-time-profile-1 · energy-profile-core-2 · cw-pv-cooling-2026-v1

Review scope: Internal review of documented model rules, worked examples, language parity and technical integration. No external expert assessment of the specific installation, equipment sizing or operating schedule has been performed.

Model maintenance: Model version cw-pv-cooling-2026-v1 · Model baseline 15 September 2026: cooling schedule in the shared hourly energy core. No hourly weather or indoor-temperature forecast. Model review by 15 September 2027.

FAQ

FAQ about Solar Air Conditioning Calculator

Does this replace the air-conditioner sizing calculator?

No. The sizing calculator helps assess room capacity, system type and seasonal electricity. This calculator uses cooling electricity and operating times to model supply from a PV system.

Is solar-powered cooling free?

Not necessarily. Self-consumption avoids grid purchases but gives up export revenue. Other loads and battery losses also affect additional value. Investment, maintenance and replacement costs are excluded here.

Can I use local PV data?

Enter your own annual yield or use the existing location lookup for PVGIS monthly values. The shared core allocates energy across typified hours within each month. It does not fetch hourly measurements or weather forecasts.

Why can the battery case show higher cooling costs?

The comparison measures additional cost against the same system without cooling. Cooling may use stored electricity that would otherwise serve the household. Extra losses or high export payments can reduce the benefit; negative values are not hidden.

How do I compare several results?

Calculate your first result, then open “Compare your scenarios and document the evidence” below it and select “Capture displayed result”. Change the inputs, calculate again and capture the next result. You can compare up to three results. Leaving or reloading the page clears the captured scenarios and notes unless you export them first.

How do I save and reopen a comparison?

In the scenario comparison, “Export comparison (CSV)” downloads a table for documentation. To reopen the comparison here later, use “Save archive for later” to download a JSON file, then import it in the same calculator. Imported results are unverified archive values. Select “Restore inputs and recalculate” and check the current result before capturing it again.

How do I change input units?

Choose the unit beside the input: W or kW for power, currency units or cents per kWh (pence for GBP; rappen for CHF). Values already entered are converted to the equivalent amount. Select your offer's currency first; no exchange-rate conversion is applied.