What size air conditioner does your room need?
Which air conditioner can keep your room comfortable on hot days? Room size, insulation, windows and sunlight affect the cooling capacity needed. Installation permission, a suitable location and noise matter too. Check the actual product data before buying; the calculation does not replace professional cooling-load and installation design.

Quick answer
How much air-conditioning capacity does a room need?
Floor area alone is not enough. Compare the calculated capacity range with the product and check which type you can install. Review noise, installation cost, condensate drainage and whether output can fall when less cooling is needed. External shading can reduce cooling demand.
What matters
Use a cooling-load range rather than a seemingly exact figure
Cooled floor area is only the starting point. The simplified calculation also considers ceiling height, envelope condition, window share, solar exposure, top-floor position, occupants and the difference between outdoor and target temperatures. Lower, midpoint and upper reference values show how incomplete building information can change the likely capacity requirement.
ENERGY STAR's official US room-air-conditioner sizing table relates area to capacity and assumes an eight-foot ceiling. It covers 100 to 2,500 ft²; the calculator does not extrapolate beyond that range. The table highlights shade and occupancy adjustments, but it is not a universal building-physics formula for every climate or construction type.
Keep cooling load and equipment-class selection separate
Room cooling load is created by the building, weather and use. It is therefore independent of equipment type; no blanket type factor may alter the capacity range.
Electricity use and cost are calculated from the entered rated cooling capacity, efficiency value, planned runtime, assumed load and electricity price. The system type is checked against your installation and usage constraints; it does not change that calculation automatically. Compare actual product data and installation cost from real quotes before buying.
The recommendation identifies a suitable system type. Multi-split and central or ducted systems require room-by-room cooling-load and system design. The single-zone range must not be treated as a sum for several rooms or as whole-home sizing.
Choose the cooling scope: single, sequential or simultaneous
Single room: The capacity calculation and system-type comparison apply to this room only. Limit: Adjacent closed rooms are not served by the result.
Connected open zone: A continuously open area is treated as one shared zone. Limit: Doorways, bottlenecks and strongly different loads can still require room-by-room assessment.
Multiple rooms sequentially: One genuinely portable unit moves between rooms and cools only one room at a time, never several simultaneously. Limit: Placement and at least one suitable exterior route must work at every location; dual-hose needs two separate, adequately sized and sealed routes at each location.
Multiple rooms simultaneously: Simultaneous cooling needs room loads and suitable indoor units, such as several single-splits, multi-split or a professionally designed ducted solution. Limit: The single-zone capacity range must not be added up or reused as total capacity.
Whole home: Multiple independently sized single-splits, multi-split or a suitable ducted system are architecture candidates only. Limit: Outdoor-unit positions, line or air paths, coincidence and every room load require professional design.
Boundary of the seven system types: Wall-mounted units, floor consoles and ceiling cassettes are indoor-unit or mounting variants within fixed single- or multi-split systems, not separate load models. Reversible air-to-air heat pumps are a product function within those types. Commercial VRF/VRV, rooftop, chilled-water and precision-cooling systems are outside this household comparison and require professional design.
Fans and evaporative coolers as separate alternatives
Fan: Creates air movement and can improve thermal comfort, but does not remove heat from the room. It is not a substitute for effective cooling during dangerous heat or excessive room temperature; self-heat, sound and safe placement still matter.
Evaporative cooler: Cools air by evaporating water and is not a conventional compression air conditioner. Performance depends on dry outdoor air and sufficient ventilation; it adds humidity and is not an equivalent substitute in humid or closed conditions. Water hygiene and maintenance require separate attention.
Connect EER, SEER and electricity cost without mixing standards
Electrical input power = cooling capacity ÷ efficiency ratio. Seasonal use applies the entered load factor to scheduled operating hours. This is your assumption about average load, not an inferred compressor curve. Hourly, daily and seasonal costs use only the entered electricity price; changing the currency symbol does not convert the amount.
EU Regulation 626/2011 distinguishes seasonal SEER values for certain air conditioners from rated EER values for single- and double-duct units. US sources may use CEER or SEER2 under different test conditions and sometimes in Btu/Wh. Enter only a measure compatible with the calculator's W/W field, or base energy planning on reliable manufacturer and metered data.
Limit summer heat gains at the building first
EU Climate-ADAPT describes shading, limiting heat gains and night ventilation as passive measures against summertime building overheating. Fans do not remove room heat, but air movement can improve comfort with much lower power demand than an air conditioner.
Passive measures cannot replace cooling or heat-health precautions in every weather condition. The numerical comparison uses only the ENERGY STAR heavy-shade reference; it does not translate night ventilation into kilowatts. When sun or roof exposure drives the upper value, improvements to the building may be more effective than simply adding rated capacity.
Understand the calculation limits before buying or installing
The model represents one room as a single thermal zone and covers mainly sensible cooling load. It does not simulate hourly weather, humidity or latent load, uncontrolled infiltration, thermal bridges, connected rooms, duct losses, electrical supply, condensate, noise propagation or refrigerant handling. Product output at a specific outdoor condition is not guaranteed from a catalogue rating.
A purchase or building intervention also requires checks for local rules, electrical connection, noise, fire safety and competent refrigerant work. Heat-sensitive occupants, complex layouts or sustained operation call for professional room-by-room load calculation, equipment selection and an installation design before ordering.
Compare seven equipment types
Installation and the pipe or air route outside must be permitted. Use the overview to shortlist options, then open each type for suitability, exclusions and required product data.
| Type | Typical fit | Key limitation |
|---|---|---|
| Single-hose portable monoblock | For one room where the unit needs to be removable, no outdoor unit is possible, and an exhaust opening can be made safe and as airtight as practical. | No safe, sealable exhaust opening. |
| Dual-hose portable monoblock | For one room with a removable unit and a suitable opening for separate outdoor-air intake and exhaust where a fixed outdoor unit is not possible. | No safe, sealed two-hose path outdoors. |
| Portable split system | For one room where an outdoor section may be positioned safely, a permitted line route exists and a unit that can be removed with few lasting changes is wanted. | No permitted, fall-safe outdoor-section position. |
| Fixed single-split | For one permanently cooled room where a permitted outdoor-unit location, line and condensate route, and professional installation are possible. | No approved, technically suitable outdoor-unit position. |
| Multi-split | As equipment-class orientation for several separate rooms where few outdoor units are possible and professional room-by-room design addresses coincident loads. | No approved outdoor location or compliant line routes. |
| Window/wall unit | For one room with a permitted load-bearing removable window installation or permanent window/through-wall installation where a packaged unit fits without long refrigerant lines. | No approved opening with adequate structural capacity. |
| Central/ducted system | Only as equipment-class orientation for several rooms or zones with suitable air paths and equipment space plus professional room-load, airflow and system design. | No technically and fire-safety-compliant supply and return routes. |
Single-hose portable monoblock
For one room where the unit needs to be removable, no outdoor unit is possible, and an exhaust opening can be made safe and as airtight as practical.
Advantages
- No permanently mounted outdoor unit is required.
- Can be installed without site-installed refrigerant lines.
- Can move between suitable locations with compatible openings.
Disadvantages
- Exhaust creates negative pressure and can draw warm outdoor air inside.
- The hose and leaky window seal add heat gains.
- The compressor and fan operate indoors and can be conspicuous.
When to rule it out
- No safe, sealable exhaust opening.
- Exhaust routing or placement is prohibited by building or lease rules.
Other limitations to check
- Highly sound-sensitive bedroom.
- Several separate rooms or sustained high load without product evidence.
Check the product data
- Rated cooling capacity, permitted outdoor range and available stages or inverter control.
- Indoor sound-power and sound-pressure data at each operating level.
- Self-evaporation, tank, continuous drain and high-humidity behavior.
- EER/CEER with unit, single-/double-duct test class and electrical input at the stated rating point.
- Hose diameter and length, maximum routing, window seal, safety and clearance requirements.
Dual-hose portable monoblock
For one room with a removable unit and a suitable opening for separate outdoor-air intake and exhaust where a fixed outdoor unit is not possible.
Advantages
- Separate intake and exhaust can reduce negative pressure and uncontrolled warm-air entry.
- No fixed outdoor unit is required.
- Condenser airflow is better separated from the cooled room-air path.
Disadvantages
- Two large hoses and a carefully sealed opening are needed.
- The compressor, fan and warm hose surfaces remain indoors.
- The unit is bulky and mobile only where hose routing is suitable.
When to rule it out
- No safe, sealed two-hose path outdoors.
- Intake and exhaust cannot be separated as the manufacturer requires.
Other limitations to check
- Frequent moves without matching openings.
- Highly sound-sensitive use or an obstructed escape route.
Check the product data
- Rated cooling capacity, stages or inverter range and permitted hose configuration.
- Indoor sound data at rated and quiet operation.
- Tank and continuous-drain design plus full-tank shutdown.
- EER/CEER and electrical input under the expressly stated double-duct test procedure.
- Intake/exhaust spacing, hose limits, window adapter, sealing and clearances.
Portable split system
For one room where an outdoor section may be positioned safely, a permitted line route exists and a unit that can be removed with few lasting changes is wanted.
Advantages
- The compressor can sit outdoors and reduce indoor noise.
- There is no exhaust-induced negative pressure as with a single-hose monoblock.
- Products designed for it can work without permanent façade mounting.
Disadvantages
- The outdoor section and connecting line require secure positioning and routing.
- The assembly is heavier and less freely mobile than the name suggests.
- Outdoor sound, condensate and line protection remain site-dependent.
When to rule it out
- No permitted, fall-safe outdoor-section position.
- The line or opening compromises an escape route, closure or manufacturer instruction.
Other limitations to check
- Daily movement between rooms.
- Noise-sensitive neighbors without a suitable outdoor position.
Check the product data
- Rated cooling capacity, control range and capacity at the relevant outdoor temperature.
- Separate indoor/outdoor sound data and night or quiet mode.
- Indoor-unit condensate path and permitted line slope.
- EER or compatible W/W value with its rating point; seasonal metrics only within their applicable scope.
- Outdoor-section weight and restraint, line length, bend radius, opening, weather protection and electrical supply.
Fixed single-split
For one permanently cooled room where a permitted outdoor-unit location, line and condensate route, and professional installation are possible.
Advantages
- Indoor and outdoor sections keep heat rejection and compressor noise outside the room.
- Modulating products can match output to one room.
- No exhaust hose, negative pressure or open window is needed.
Disadvantages
- Penetration, mounting, electrical and refrigerant work require design and professional execution.
- The outdoor unit affects the façade or outdoor space and produces outdoor sound.
- One indoor unit does not reliably cool separate rooms behind closed doors.
When to rule it out
- No approved, technically suitable outdoor-unit position.
- No compliant line, condensate or electrical connection can be provided.
Other limitations to check
- Short rented occupancy without installation consent.
- Several separate rooms with only one indoor unit planned.
Check the product data
- Rated, minimum and maximum output plus derating at the outdoor design temperature.
- Indoor and outdoor sound at each level, clearances and possible structure-borne noise.
- Gravity fall, pump where needed, frost-safe routing and accessible discharge.
- EER at rated point, SEER in the relevant climate profile and electrical input at material part- and full-load points.
- Permitted line lengths and elevation, wall construction, outdoor support, power supply and commissioning by a qualified installer.
Multi-split
As equipment-class orientation for several separate rooms where few outdoor units are possible and professional room-by-room design addresses coincident loads.
Advantages
- Several indoor units can serve separate rooms directly.
- One outdoor unit can reduce the number of visible outdoor sections.
- Room-level control is possible with an approved system combination.
Disadvantages
- Available total output and diversity are limited by the shared outdoor unit.
- Refrigerant lines, condensate routes and commissioning are more complex than one single-split.
- Part-load behavior and efficiency depend on the exact indoor/outdoor combination.
When to rule it out
- No approved outdoor location or compliant line routes.
- The indoor/outdoor combination is not manufacturer-approved.
Other limitations to check
- No room-by-room loads or unknown coincidence.
- Very different use patterns better served by independent systems.
Check the product data
- Combination table, total and room output under coincidence, minimum output and permitted connection ratio.
- Sound from every indoor unit and the jointly loaded outdoor unit.
- A separate drain for every indoor unit, pump needs and maintenance access.
- Efficiency of the exact approved combination at relevant occupancy and outdoor temperature, not a stand-alone unit value.
- Total line length, branches, elevation, refrigerant charge, electrical supply and room-by-room commissioning.
Window/wall unit
For one room with a permitted load-bearing removable window installation or permanent window/through-wall installation where a packaged unit fits without long refrigerant lines.
Advantages
- The refrigeration circuit is sealed as a factory package.
- There is no long exhaust hose or associated room negative pressure.
- It provides room-specific installation without a separate remote outdoor unit.
Disadvantages
- The window opening, view and weather seal are affected during use; a through-wall installation affects the façade permanently.
- The compressor sits in or at the opening and can transmit indoor and structure-borne noise.
- Fit, sealing and condensate drainage must match the building precisely.
When to rule it out
- No approved opening with adequate structural capacity.
- Fire safety, escape route, façade rule or safe drainage would be compromised.
Other limitations to check
- Heritage or façade protection.
- A sound-sensitive room with resonance-prone lightweight construction.
Check the product data
- Rated cooling capacity, stages or inverter range and permitted wall/window dimensions.
- Indoor, outdoor and possible vibration data with the correct sleeve.
- Required outward fall, drainage, splash-water and frost design.
- EER/CEER or the applicable label metric with test method and electrical input.
- Weight, structural support, sleeve, air-short-circuit clearances, sealing, weather protection and power supply.
Central/ducted system
Only as equipment-class orientation for several rooms or zones with suitable air paths and equipment space plus professional room-load, airflow and system design.
Advantages
- Conditioned air can be distributed to several zones through a designed duct system.
- Visible room units can be reduced depending on system design.
- Filtration, outdoor air and heat recovery can be integrated in systems specifically designed for them.
Disadvantages
- Design, building and commissioning effort is substantial.
- Duct losses, balancing, return air, fire safety and airflow noise affect real performance.
- Without genuine zoning, rooms can be over- or under-supplied.
When to rule it out
- No technically and fire-safety-compliant supply and return routes.
- No professional room design, condensate, electrical or maintenance plan is available.
Other limitations to check
- Retrofit for one small room.
- Insufficient ceiling, shaft or equipment space for duct sizes and service.
Check the product data
- Room loads, total coincident output, compressor modulation, airflow and external static pressure.
- Fan and airflow noise, attenuation, terminals, equipment room and outdoor source.
- Pans, fall, traps, pumps, leak detection and hygienic maintenance access.
- Whole-system efficiency including fans and duct losses at actual load, outdoor temperature and static pressure.
- Supply and return ducts, insulation, leakage, fire dampers, zoning, hydronic or refrigerant circuit and professional commissioning.
Examples and comparisons
30 m², 3.5 kW of cooling and 358.3 kWh per season
Load this example’s inputs in the calculator. Review them, calculate the result, then adapt the values to your own case.
Efficiency sensitivity
Reducing efficiency from 3.2 to 2.6 raises seasonal electricity from 358.3 to 441 kWh
Input and energy effect
| Scenario | Efficiency ratio | Seasonal electricity |
|---|---|---|
| Scenario 1 | 3.2 W/W | 358.3 kWh/season |
| Scenario 2 | 2.6 W/W | 441 kWh/season |
| Change from scenario 1 to scenario 2 | 82.7 kWh/season · +23.1% relative | |
Also verify before making a decisionThe comparison holds capacity, 504 scheduled hours, a 65% load factor and unit price constant. Real controls, weather, humidity and equipment losses can shift consumption.
Assess your case
Decision check
What the result can tell you
The single-zone band indicates plausible rated capacity for the assessed room; equipment class does not change that load.
Single- and dual-hose monoblock, portable split, fixed single-split, multi-split, window/wall and central/ducted systems are assessed separately.
Tenancy and permission, outdoor-unit space, room count, mobility, noise, budget, available openings, heating needs and existing ducts narrow the choice.
Final selection needs real output, modulation, sound, condensate, efficiency and installation data; multi-split and ducted systems also need professional design.
If-then rules for capacity and equipment class
Exclude permanent penetrations, façade changes and permanently mounted outdoor equipment for now. Check removable products against the lease, building rules, a safe opening and permitted outdoor placement.
Portable and fixed split equipment is not viable. A monoblock or window/wall unit remains a candidate only if exhaust or opening, sound, condensate and building rules are resolved.
Separate the cases: sequential rooms admit only genuinely movable classes and never simultaneous cooling. For simultaneous cooling, do not use the single-zone band as a total; calculate room loads, then assess several single-splits, an approved multi-split combination or a professionally designed ducted system.
Separate the wish for fewer outdoor units from technically independent room systems. Multi-split can consolidate outdoor units; multiple single-splits need several permitted positions but can separate use patterns and technical dependencies more strongly. Without a preference, both remain visible as distinct candidates.
Compare single- and dual-hose monoblocks with a portable split at every intended location. The outdoor section, hose or line route, seal, weight and condensate handling must work there in practice.
Compare declared indoor and outdoor sound at relevant operating levels together with mounting and possible vibrations transmitted through the building. Do not infer a blanket winner from equipment class alone.
Separate appliance, installation, building work, maintenance and operation. A removable product may be suitable, but the decision needs real quotations and compatible efficiency data instead of blanket cost assumptions.
Without an exterior route, monoblock and portable split are not viable. One route can serve single-hose exhaust or a suitable portable-split line, not dual-hose. An expressly permitted removable window installation can admit a suitable window unit; split, multi-split, through-wall and ducted systems require a permitted permanent penetration or installation.
Require a declared reversible heat-pump function, heating output, operating limit and suitable efficiency metric at the winter operating point. Do not transfer cooling performance into a heating promise.
Treat a central solution only as an equipment-class candidate. Professional design must confirm airflow, pressure loss, zones, return air, sound, fire safety, condensate and room loads.
Treat the appliance as potentially undersized. On hot design days it may run continuously at high output and still miss the target temperature. Check its capacity at the relevant outdoor temperature and the actual peak load.
Do not assume that larger is safer. What matters is whether the actual unit can modulate down to the required part load. Otherwise it may cycle more often, add avoidable cost and remove humidity less effectively. Additional zones or unmodelled loads justify a higher rating only after professional review.
Identify its test method and unit first. This calculator expects the stated ratio of cooling output to electrical input in W/W; US Btu/Wh figures and seasonal metrics must not be copied as though every number were interchangeable.
Use the ENERGY STAR table comparison for heavy shading. The calculator does not quantify the benefit of night ventilation because weather, safe window opening and air changes are unknown. Also consider humidity, outdoor air and protection from dangerous heat.
Checklist
Quick purchase and sizing checklist
- Measure only the area that will genuinely be cooled as one zone and record the actual ceiling height.
- Review glazing share, solar orientation, shading, envelope condition and top-floor exposure separately.
- Use a local outdoor design temperature and a realistic indoor target rather than a preference without weather context.
- Compare the cooling-load band with rated capacity in kW and its corresponding Btu/h value.
- Identify the unit and test method behind EER, SEER, SEER2 or CEER before deriving electricity cost.
- Resolve tenure and permission, outdoor space, room count, mobility, sound, budget, opening, heating need and existing ducts.
- For each product compare rated and minimum output, indoor and outdoor sound, condensate route, efficiency operating point and installation limits.
- Test external shading and cool night ventilation before making extra appliance capacity the only response.
Common mistakes
Common mistakes
Rooms with identical area can have very different cooling loads because of ceiling height, glazing, roof exposure, sun and envelope quality.
Oversizing can promote cycling, higher cost and weak humidity removal; the unit's modulation range and the actual peak load both matter.
Rated point, season, test procedure and unit differ across metrics and markets, so the same number does not automatically describe the same energy use.
Scheduled runtime and equivalent full-load hours are not identical; the load factor remains your assumption for average operating load.
Shading and night ventilation can lower gains, while humidity, infiltration, connected rooms and installation still require separate technical assessment.
Real output, modulation, sound and efficiency depend on the actual product and operating point. Class narrows suitability but replaces neither product comparison, quotation nor professional design.
Can the air conditioner be installed in your home?
For tenants, start with installation permission, a permitted route outside for pipes or hoses, and space for any outdoor unit. Owners check the same technical conditions and, where relevant, shared property and local requirements. Then consider room layout, the lowest cooling output the unit can maintain, noise, removal of condensed water and total installation costs. A suitable calculated capacity alone does not make a system type suitable.
- I have checked installation permission, routes outside for pipes or hoses, and space for an outdoor unit. The arrangement suits the room layout.
- For the actual unit, I have checked the stated and lowest cooling output, noise and how condensed water is removed.
- Only then are offers compared using the same efficiency convention and full installation costs.
Calculator for this guide
Match the equipment to the room and installation
The capacity range supports an initial shortlist. For a permitted system type, check actual cooling output, modulation, indoor and outdoor sound, condensate and installation costs against the quote. External shading can change demand and should be assessed before purchase.How the calculation works
Calculation
Calculation method and model limits
The calculation uses room size, ceiling height, windows, sunlight, insulation, roof exposure, occupants and temperature difference to calculate a cooling-capacity range. Capacity appears mainly in BTU/h in US mode and kW in metric and UK modes. Costs use the selected currency symbol without exchange-rate conversion. A desired heating function is considered when comparing types; the cooling result is not a heating-load calculation.
Floor area and ceiling height define the cooled volume for the single-zone assessment.
Envelope condition, window share, sun, top-floor exposure, occupants and temperature difference change the calculated capacity requirement.
Lower, midpoint and upper reference values communicate the model range of the simplified building profile.
Rated cooling capacity is shown as below, within or above the guidance range.
Rated cooling capacity divided by a compatible efficiency ratio gives electrical input power for the calculation.
Hours per day, days per week and season length create scheduled runtime; the load factor turns it into equivalent full-load hours.
Electricity use multiplied by the entered price gives cost. Heavy shading is shown as a separate comparison.
The output combines a cooling-load band, sizing status, presentation in kW and Btu/h, electrical input, runtime and seasonal cost. Every figure remains conditional on the room, efficiency, operating and price assumptions entered.
Simplified formula
Midpoint reference = ENERGY STAR area value after its official sunlight and occupant adjustments × bounded Calc‑World correction factor for ceiling height, temperature difference, envelope, window share and top-floor exposure; the range is 15% below and above that midpoint. Electrical input power = rated cooling capacity ÷ efficiency ratio. Scheduled runtime = hours/day × days/week × season weeks; equivalent full-load hours = scheduled runtime × load factor. Seasonal electricity = electrical input power × equivalent full-load hours; seasonal cost = seasonal electricity × unit price.
Units and conversions
1 kW equals 1,000 W. Power describes the rate of energy use or generation; energy in kWh equals average power in kW × time in hours. 60 minutes equal one hour, so 90 minutes are 1.5 hours, not 1.9 hours. 100 cents equal one euro or dollar, 100 pence equal one pound and 100 rappen equal one Swiss franc. A price per kWh is multiplied by the energy consumed. All monetary amounts in a calculation must use the same currency. No exchange-rate conversion is applied.
Scope and assumptions
- Calculation
- Based on your inputs
- Applies to
- International
- Currency
- Selectable display currency; no exchange-rate conversion
- Units
- Selectable unit display; metric, US and UK units are supported
- Based on
- ENERGY STAR room-air-conditioner sizing guidance, NIST unit conversion and EU energy-label context
- Calculation baseline
The examples use fixed reference values. For your own comparison, all prices must use the same currency. Changing currency does not convert the amounts.
FAQ about the Air Conditioner Calculator
Is the calculated cooling load a binding system design?
No. It is a simplified calculation for one room and does not replace room-by-room load calculation, product selection or installation design.
Why does the calculator show both kW and Btu/h?
Both units express the same cooling rate. Using the NIST factor, 1,000 watts corresponds to about 3,412.14 Btu (IT)/h; conversion does not change physical capacity.
What does an efficiency ratio of 3.2 mean?
Here it means 3.2 units of cooling output for each unit of electrical input at the assumed operating point. Confirm that the product document provides a compatible W/W figure.
Why can an oversized air conditioner be a poor choice?
An oversized unit may cycle more often, cost more and remove humidity less effectively for some designs. Product-level modulation and latent-load performance need separate review.
How do shading and night ventilation affect the result?
The heavy-shade comparison follows the ENERGY STAR table. The benefit of night ventilation is not calculated because window opening, weather, security and air changes are unknown.
Can the result be used for several rooms or an entire home?
Only when the assessed area truly behaves as one thermal zone. Separate rooms, doors, airflow paths and differing exposures require room-by-room professional analysis.
Which air-conditioner classes does the guide compare?
It distinguishes single- and dual-hose monoblocks, portable split, fixed single-split, multi-split, window/wall and central/ducted systems. Fans and evaporative coolers are separate alternatives, not conventional compression air conditioners.
Does selecting an equipment class automatically change electricity cost?
No. The cooling-load band remains independent of class. The calculator derives use and cost from entered capacity, a compatible W/W value, operation and unit price; a purchase requires real product data and quotations.
We test the worked example automatically with the same logic used by the calculator. Sources, inputs, rounding and model limits are listed separately. This does not replace case-specific professional advice.
Responsible editor: Jens Marx
- Calc‑World: calculation methods, model limits and quality process
- ENERGY STAR: sizing room air conditioners and avoiding oversizing
- US Department of Energy FEMP: purchasing energy-efficient room air conditioners
- EU Climate-ADAPT: shading, ventilation and passive measures against excessive building heat
- EU Regulation 626/2011: energy labelling of air conditioners
- NIST Guide to the SI: BtuIT/h to watt conversion factor
Primary sources, units, sizing and energy identities, appliance and efficiency terminology, model boundaries, international context and DE/EN parity were reviewed. No external cooling-load or installation assessment was performed.