Calculator

Air Conditioner Size Calculator

What size air conditioner does your room need? Compare system types and calculate electricity use and running costs.

Start calculating – enter your values
Bright living room with a wall-mounted air conditioner and a light sofa.
Illustrative image
Inputs

Calculate now

Guide & worked examples

Use your room's size and conditions to calculate a cooling-capacity range and check running costs. The model starts with the ENERGY STAR capacity table for room air conditioners and its solar and occupancy adjustments, then applies bounded corrections for ceiling height, temperature difference, building envelope, window share and roof exposure. The system-type comparison considers your home, installation conditions and whether a heating function is wanted.

Display currencyChoose the currency for inputs and results. Numeric values and the model basis stay unchanged; no exchange-rate conversion is applied.
UnitsMetric units are the international default. Switch to US or UK units for floor area, ceiling height, temperatures and rated cooling capacity when your comparison uses them.
The ENERGY STAR table covers rooms from 100 to 2,500 ft² (about 9 to 232 m²). The calculator stops outside this range.
ENERGY STAR includes two occupants and adds 600 BTU/h for each additional person.
Use a typical high outdoor temperature at which the room still needs reliable cooling. It must be above the indoor target temperature.
The calculator derives the temperature difference from the outdoor and target temperatures. It changes the modelled value only within fixed limits; humidity and latent load are not modelled.
Use the data-sheet value and compare it with the guidance range. A substantially higher rating is plausible only if additional zones or loads outside the model are established professionally. For inverter units, check the minimum modulation capacity in particular.
The value is used exactly as entered. Enter a W/W data-sheet or scenario value; US BTU/Wh ratings are not silently converted.
The calculator checks this system type against your home and installation conditions. The selection changes neither the calculated cooling-capacity range nor the energy and cost calculation. Those figures come from the entered product and operating data; use the actual product data before buying.
Landlord approval does not replace any other building, community or local permissions.
The calculated cooling load always covers the entered zone only. Multiple rooms and whole-home systems require professional room-by-room design.
For sequential multi-room use, select only if safe placement works in every intended room. For simultaneous rooms or a whole home, this confirms enough permitted positions for the architecture being considered.
A dual-hose unit needs two separate, adequately sized and sealed routes. One route is sufficient only for single-hose exhaust or a suitable portable-split connection. For sequential multi-room use, the selected number must be available in every intended room.
A removable window installation applies only to window units designed for it. Split, multi-split, through-wall and ducted solutions require the permanent-penetration/installation option. Ownership does not replace building, façade or community approval.
For a more detailed assessmentBuilding, operation and comfort detailsStandard assumptions active
ENERGY STAR uses an 8 ft reference. For higher ceilings, the calculator raises the modelled value with a bounded correction factor.
This choice applies a bounded correction to the modelled value: well protected 0.92, average 1.00, poorly protected 1.10. It is not a standards-based cooling-load calculation.
The calculator uses 0.96 for a low window share, 1.00 for medium and 1.08 for high. Glazing, frames and shading are not modelled in detail.
A user-set scenario assumption. 65% means the scheduled hours are treated as 65% equivalent full load.
Use your own unit rate. The symbol is a display currency only; no exchange-rate conversion is performed.
The recommendation does not replace comparing actual indoor and outdoor sound data from the product sheet.
This refers to installation work, not a fixed price. Compare real all-in quotes afterwards.
Air Conditioner Size Calculator: preparing the calculation logicThe calculation starts only after you submit the form. Until then, Calc‑World deliberately shows no provisional result. The method, interpretation and model limits remain readable on this page.
Model scope, review and sourcesScope, model baseline and responsible sources
Transparency

Scope and assumptions

Model
Based on your inputs
Reference region
International
Currency
Display currency EUR; no exchange-rate conversion
Units
Metric display; metric, US and UK units are supported
Reference basis
ENERGY STAR room-air-conditioner sizing guidance, NIST unit conversion and EU energy-label context
Reviewed model baseline
Responsibility & review

Who is responsible for this model

Find out who is responsible for this content, what has been checked, how the calculation works and which primary sources it uses. If no external professional review is named, none has taken place.

Responsible editor
Jens Marx
Latest editorial and technical review
Review
Internal editorial and technical review
Calculation basis
Room-cooling screening model v1 · Room-cooling device-decision model v1 · cw-room-cooling-screening-2026-v1

Review scope: Primary sources, units, sizing and energy identities, appliance and efficiency terminology, model boundaries, international context and DE/EN parity were reviewed. No external cooling-load or installation assessment was performed.

Model maintenance: Model version cw-room-cooling-screening-2026-v1 · source and assumption baseline 19 August 2026 · mandatory review due 19 February 2027. This is a screening model, not a professional cooling-load calculation.

FAQ

FAQ about Air Conditioner Size Calculator

Is this a professional cooling-load calculation?

No. It is an initial planning reference based on the ENERGY STAR capacity table and listed Calc-World corrections. Professional design requires more detailed building, weather, humidity and ventilation data.

Why are kW and BTU/h shown together?

Products use both units across markets. The calculator uses the project-wide NIST-based factor 1 kW = 1,000 ÷ 0.2930711 BTU/h and displays both together.

Is a unit above the guidance range automatically oversized?

Not automatically. Check whether the actual unit can reduce output to the required part load. Otherwise it may cycle more often, add avoidable cost and remove humidity less effectively. Additional zones or unmodelled loads justify a higher rating only after professional review.

How are seasonal electricity and cost calculated?

They use entered rated cooling capacity, operating hours, days, season weeks, load factor, W/W efficiency and electricity price. There is no hidden weather or tariff forecast.

What does the ±20% sensitivity mean?

It separately shows the effect of 20% more or less runtime or electricity price. It is not a confidence interval or weather forecast.

How do I compare several results?

Calculate your first result, then open “Compare your scenarios and document the evidence” below it and select “Capture displayed result”. Change the inputs, calculate again and capture the next result. You can compare up to three results. Leaving or reloading the page clears the captured scenarios and notes unless you export them first.

How do I save and reopen a comparison?

In the scenario comparison, “Export comparison (CSV)” downloads a table for documentation. To reopen the comparison here later, use “Save archive for later” to download a JSON file, then import it in the same calculator. Imported results are unverified archive values. Select “Restore inputs and recalculate” and check the current result before capturing it again.

How do I change input units?

Choose the unit beside the input: W or kW for power, minutes or hours for durations, currency units or cents per kWh (pence for GBP; rappen for CHF). Values already entered are converted to the equivalent amount. Select your offer's currency first; no exchange-rate conversion is applied.